pH/ORP Monitor & Controller

prod_499cdb3429f65_EC-ALPHA560_controllers-pH560.jpg
prod_499cdb3429f65_EC-ALPHA560_controllers-pH560.jpg

pH/ORP Monitor & Controller

$702.90

Thermo Scientific ALPHA560 pH or ORP controller.

In Stock: 1 available

To purchase our products online please use our new online store using the button below

  • The Alpha COND 560 controller simplifies process control with separately adjustable high/low hysteresis, and two switching contacts that act as set-point relays. Advanced control feature allows user to set alarm delay of up to 2000 seconds, preventing false alarms and unnecessary down-times.
  • Plus or minus 1 % accuracy across six Conductivity ranges.
  • Separately adjustable High/Low hysteresis with user-adjustable time delay of up to 2000 seconds for minimal chattering and false alarms.
  • User-selectable range, cell-constant and temperature coefficient to suit different application needs, including pure water measurements.
  • Two switching contacts as set-point relays.
  • Large UV Light protected LCD with backlight.
  • Push button operation for easy set-up programming and customization.
  • Reliable, accurate measurements at different temperature with Automatic Temperature Compensation.

Specifications:

  • Conductivity:</b>
  • Range: To 2 micro second/cm ;to 20 micro second/cm ;to 200 micro second/cm ; to 2000 micro second/cm ;to 20 micro siemens/cm ; to 200 micro siemens/cm.
  • Resolution: 0.001 micro second/cm, 0.01 micro second/cm, 0.1 micro second/cm, 1 micro siemens/cm, 0.01 micro siemens/cm, 0.1 micro siemens/cm.
  • Accuracy: Plus or minus 1 % full scale.
  • Cell Constant: k = 0.1, 1.0, 10.0.

Temperature:

  • Range: -10.0 to 125.0 degree Celsius / 14.0 to 157.0 degree Fahrenheit.
  • Resolution: 0.1 degree Celsius / 0.1 degree Fahrenheit.
  • Accuracy: Plus or minus 0.5 degree Celsius / plus or minus 0.9 degree Fahrenheit.
  • Sensor: Pt100 2 or 3 wire.
  • Compensation: Auto/manual.
  • Coefficient: 0 to 10 % (selectable).
  • Normalization: 20.0 to 25.0 degree Celsius (selectable).
  • Controller:
  • Set Point 1 (SP1): To 2 micro seconds/cm or to 20 micro seconds/cm.
  • Point 2 (SP2:)200 micro seconds/cm or to 2000 micro seconds/cm or to 20 micro siemens/cm or to 200 micro siemens/cm.
  • Switching Conductivity Hysteresis: 0 to 10 % full scale reading.
  • Function (Switchable): Limit control Off.
  • Pickup/Dropout Delay: 0 to 2000 sec.
  • Contact Outputs: 2 SPST relays.
  • Switching Voltage/Current Power: 1/8 HP at 125 VAC / max. 0.74 A / max. 93 VA 1/8 HP at 250 VAC / max. 0.37 A / max. 93 VA.

Electrical Data And Connections:

  • ;Conductivity Input: 2-pin terminal.
  • Connection Terminal: 2-pin & 8-pin terminal, detachable blocks, DC jack.
  • Display:
  • LCD: 7 segments display with symbols for status information.
  • Backlight: Yes (on/off selectable).
  • Power Supply:</b>
  • Input:12 to 24 V DC or 9 V DC.
  • EMC Specifications:</b>
  • Emitted Interference: According to EN 61326.
  • Immunity To Interference: According to EN 61326.
    Environmental Conditions:
  • Operating Temperature Range: 0 to 40 degree Celsius.
  • Max. Relative Humidity: 80 % up to 31 degree Celsius decreasing linearly to 50 % at 40 degree Celsius.
    Mechanical Specifications:
  • Dimensions: (WxHxD) 96 x 96 x 66 mm.
  • Weight: 210 g (unit) / 310 g (packed).
  • Ingress Protection: IP65.

Reviews

There are no reviews yet, would you like to submit yours?

Be the first to review “pH/ORP Monitor & Controller”